For Edmonton-area homes with a Lifebreath RNC6-ES or RNC205 HRV, or a bathroom fan used as the home’s primary ventilation system. Start by identifying your system: the controls work differently.
Start with a humidity reading
- Measure the air in a living area. Use a hygrometer (a small indoor humidity meter), away from a shower, cooking steam, supply register or direct sunlight. Check morning and evening and note the outdoor temperature.
- Check the windows too. Water or frost on the room side of the glass is a reason to review moisture and ventilation. Wipe up water promptly. Moisture between sealed panes needs a window assessment, not a lower HRV setting.
- Choose the matching instructions below. An HRV has a ventilator unit and a wall control. A primary bath-fan system uses an exhaust fan and a labelled ventilation switch or controller. Do not use HRV button instructions on a bath-fan system.
Where to find the controls
In our homes, the main thermostat and HRV wall control are usually near each other on the main floor. The labelled ventilation switch for a primary bath-fan system is usually on the main or second floor; for a secondary suite system, look in the basement. The humidistat is usually on the return-air duct in the mechanical room. Locations can vary: use the labels and your handover instructions to identify the control for your own system.
A starting point for Edmonton seasons
RH means relative humidity. Health Canada’s general household range is 30–50% RH. ATCO’s Alberta homeowner guidance suggests the seasonal starting ranges below. They describe the measured room humidity, not a fan-speed setting or a guarantee against condensation.
| Conditions | Starting range |
|---|---|
| Heating season | About 30–35% RH |
| Warmer months | About 40–50% RH |
| A cold snap | Watch the windows; a lower level may be needed. |
Cold glass can collect moisture even within these ranges. Window construction, coverings, indoor temperature and outdoor weather all matter. Do not keep a higher target while water or frost is accumulating. Persistent condensation, or the need to keep the home very dry to avoid it, deserves an assessment.
Our homes also have a humidifier. Before a cold spell, review its setting as well as the room humidity. A humidifier adds moisture; an HRV dehumidistat requests extra ventilation to remove it when conditions allow. The summer range above is not an instruction to run the humidifier until the house reaches 40–50%.
Sources: ATCO: Alberta seasonal humidity (opens external resource) · Health Canada: moisture and mould (opens external resource) · FGIA: window condensation (opens external resource)
Humidifier: add only the moisture needed
The humidistat is usually mounted on the return-air duct in the mechanical room. It controls added moisture. On a manual dial, the percentage is a requested setting, not a live reading of humidity in your living room. Check a separate humidity meter in a living area; the air beside the duct-mounted control is not the same measurement.
- Use the instructions for your actual control. Humidifiers and their controls vary by model. A return-duct location does not tell you whether the control is manual or automatically adjusts for outdoor temperature. Use visible model information and the supplied manual; leave covers, wiring and installer settings alone.
- Lower a manual setting as the weather gets colder. Follow the outdoor-temperature chart on your control or in its matching manual. The 30–35% winter range above is not a setting to hold through every Edmonton cold snap. If water or frost appears on the room side of windows, reduce added humidity and wipe up the water promptly.
- Adjust and observe. Move a manual control towards a lower humidity number for less added moisture, or higher for more, within its instructions. Check the room reading and windows as conditions settle. Do not keep turning it up because the house does not respond immediately. If the home remains dry or wet, ask us to check the settings and equipment.
For summer shutdown, follow your particular humidifier’s owner manual. Water, power and any seasonal damper instructions depend on the model. Do not apply another model’s shutdown steps to your equipment.
Use the owner instructions supplied with your humidifier and humidistat. The control model determines its settings and seasonal shutdown steps.
Lifebreath RNC6-ES and RNC205: ventilation first
Keep the normal mode and speed specified at installation. Lifebreath recommends continuous low-speed ventilation while windows are closed, with a temporary boost when needed. If your home has a different installed schedule, follow it; the right speed number is not the same for every installation.
During the heating season
If normal ventilation is not controlling excess moisture, use the wall control’s dehumidistat. A lower threshold calls for more drying ventilation. Start with the coordinated settings supplied for your humidifier and HRV, then check the actual room reading and windows. Do not automatically put both controls at the same percentage.
Change one available step at a time. If the home is already dry, do not lower the threshold: keep normal ventilation and review whether extra dehumidification is needed.
Outside the heating season
Set the dehumidistat function to OFF as the matching Lifebreath instructions direct. Keep normal ventilation operating. This does not mean switching the HRV’s power OFF.
An HRV is not a refrigerant dehumidifier. Warm, damp outdoor air may increase indoor moisture; air conditioning or a separate dehumidifier may be needed.
Use the installed bathroom timer or boost control for showers. When the boost ends, return to the home’s normal ventilation operation. Recirculation moves indoor air around; it does not bring in fresh air. Do not select a recirculation-only mode as a substitute for required fresh-air exchange.
Lifebreath owner manuals: RNC6-ES · RNC205. See printed pages 4–6 for operation and dehumidification; pages 7–11 for wall controls. Health Canada: ventilation and indoor humidity (opens external resource)
Match the control on your wall
The HRV wall control is usually near the main thermostat on the main floor in our homes. It is separate from the humidifier control, which is usually on the return-air duct in the mechanical room. The HRV’s model number does not identify its wall control. Check visible model information or the supplied instruction card; do not remove wiring or the control from the wall to find it.
BC02 / BC03
Use the Dehumidistat button to cycle the humidity lights to the desired available level. After releasing the button, wait a few seconds. A flashing humidity light indicates a dehumidification demand; a steady light means humidity is below the selected threshold. To disable only this function, cycle until its humidity light is off.
Leave the fan/mode at the normal ventilation setting. BC03’s mode button changes ventilation operation; it is separate from the humidity button.
DXPL02 / DXPL03 digital control
The large number is the current humidity; the small number is the dehumidistat threshold. Use the Dehumidistat button to adjust the threshold. If humidity exceeds it, the control calls for high-speed ventilation, then returns to the earlier setting.
Do not press RESET for a seasonal adjustment: it changes other settings too. Follow your instruction card for the exact buttons and available options.
BC04 or a different control
BC04 has fan and 20/40 controls but no built-in humidity adjustment. Use a separate humidity meter and follow the installed ventilation instructions. For another control model, use its own manual; these button sequences may not apply.
Manual references: BC02 page 7; BC03 page 8; BC04 page 9; DXPL02/DXPL03 pages 10–11. If the PDF does not open, use the manufacturer product-page links in our manual library and choose Residential HRV Homeowners Manual.
Homes with a labelled ventilation switch
Look for the labelled switch on the main or second floor. For a secondary suite’s ventilation system, it is usually in the basement. Use the switch for the system serving your own home or suite.
Some Heating and Cooling Doctor Ltd. installations use a 50 CFM or 80 CFM bath fan as the home’s primary exhaust ventilation fan. For these installations, our normal operating instruction is to leave the labelled ventilation switch ON. This supports the intended fresh-air exchange and, where interlocked with the furnace blower, air circulation and temperature distribution. CFM describes airflow, not a humidity target; a simple switch has no percentage to set.
- Leave the labelled ventilation switch ON. Do not turn it off when a shower ends or because the humidity reading looks comfortable. Keep any installed furnace-fan interlock operating. Follow the handover instructions for your particular controls.
- Use bathroom exhaust during showers and afterwards. HVI recommends continuing local bathroom ventilation for about 20 minutes after use. This is extra moisture removal, not the whole-home ventilation schedule. If the same fan provides both, keep its primary-ventilation operation afterwards.
- Keep the air path clear. Keep the fan grille and intended door-gap or transfer path unobstructed. Some systems bring replacement air through the furnace and may run its blower with the ventilation switch. Leave that interlock operating as installed.
- Use a room humidity meter. If the fan has a separate humidity sensor or timer, follow that model’s instructions. Do not change hidden speed switches, wiring, dampers or installer programming to chase a humidity number.
HVI: bathroom ventilation and after-shower operation (opens external resource) · HVI: airflow and ventilation background (opens external resource)
If the reading or windows still do not look right
- Too humid or windows wet
- Use the shower exhaust and kitchen hood, reduce avoidable moisture sources and check accessible outdoor hoods from ground level for snow or leaves. Wipe up water. If moisture returns, have the ventilation and building checked rather than repeatedly increasing fan operation.
- Too dry
- Check the reading with a humidity meter and review the HRV’s extra drying demand. Keep required ventilation. An HRV does not add moisture; persistent dryness needs a review of settings, ventilation and any humidifier.
- Automatic warm-weather dehumidistat disabling
- Lifebreath describes automatic warm-weather disabling of this function above 15°C for 24 hours. Other ventilation functions continue. Do not reset or unplug the unit to force dehumidification in summer.
- Fan noisy, not running, leaking or still leaving the room damp
- Report the symptoms and model to our team. Do not climb to a roof outlet, alter ducts or open electrical compartments. Mould, recurring ice or water damage need investigation; a control adjustment alone may not solve the cause.
Manuals and further guidance
- Lifebreath RNC6-ES manual and manufacturer page
- Lifebreath RNC205 manual and manufacturer page
- Lifebreath wall-control product information (opens external resource)
- Routine care and HRV filter cleaning
- Room supply-register and seasonal comfort guide
Need help with your installed settings? Contact Heating and Cooling Doctor Ltd. with the HRV or fan model, wall-control model, room humidity, outdoor temperature and what you notice at the windows.
Homeowner operating guidance, not a ventilation design or a substitute for your equipment instructions. Sources checked October 29, 2026.